Respiratory Ventilator Medical PA 700B
Ventilator with a medical air compressor(PA-700B)
- The Ventilator is a universal multi-mode Ventilator, a multi-functional Ventilator, which can be used for clinical breath first aid and respiratory therapy.
- With the control, auxiliary/control, intermittent instruction, manual and other breathing patterns, as well as breathing is not positive pressure, sigh and other respiratory function is the hospital���s essential breathing equipment.
- Large-screen LCD display, 10.4 inch TFT color LCD screen. Dual flow sensor to ensure that the breath and inhale more secure, accurate.
- Power-off-delay function.
- Display: 10.4��� LCD Display
- Mode:: a pneumatically powered and electrically controlled system
- Trolley:: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot-operated brake provisions
- Technical Specifications:
- Gas requirement:: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
- safety valve: <12.5 kPa
- Respiratory Rate: 1 ~ 99 bpm
- Oxygen Concentration: 21% ~ 100%
- Maximum Minute ventilation: ���18L / min
- modes of ventilation: A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT
- Ventilator compliance: ���30 Ml/kPa
- PEEP:: 0 ~ 1.0 kPa
- Ptr:: -10 ~ 10 hPa
- IMV frequency:: 1~20 bpm
- I/E Ratio:: 4:1~1:4, Has the inverse ratio ventilation
- Tidal Volume: Setting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10ml
- Inspiratory Plateau:: 0~1s
- Maximum Safety Pressure: ��� 6.0kPa
- Sigh:: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
- Pressure limit range:: 1.0~ 6.0kPa
- Airway pressure alarm: Audible and visual and with yellow and red color indicating: Lower: 0.1 kPa ~ 6.0 kPa; Upper: 0 ~ 5.0 kPa
- ��0.2 kPa
- Ventilation Volume alarm:: ��� 18L/ MIN
- Power Supply Alarm: Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s
- Operating conditions
- Ambient temperature:: 10 ~ 40oC
- Relative humidity:: no higher than 80 %
- Atmospheric pressure:: 860 hPa ~ 1060 hPa
- Power requirement:: 100-120 Vac, 50/60 Hz;
- Attention: the AC power supply used for the anesthesia the machine must be well-grounded.
- Storage
- Ambient temperature:: -15oC ~ +50oC
- Relative humidity:: no higher than 95 %
- Atmospheric pressure:: 86 kPa ~ 106 kPa.
- It should be stored in a room without corrosive gas and well ventilated
- Package
- packaging box: comply with the requirement of GB/T 15464
- Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
- Moisture protection and rain protection to ensure that product is protected from natural damage.
- Safety & Alarm
- Gas source pressure: Immediate alarm; ���high level alarm��� indicator flickers raising an audible alarm.
- Airway Pressure Alarm: The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The ���high-level alarm��� indicator flickers raising an audible alarm.
- Tidal Volume Alarm: Lower than 50ml, The alarm will be raised after one breathing cycle.
- Ventilation Volume Alarm: Lower: 0~12L/Min; Up: 18L/ Min
- Battery Voltage Alarm: It alarms when the battery voltage is lower than 10.5V.
- Power On Self Test: Self-test before working, assure it���s working normally.